MULTIQUIP LS600P Bedienungsanleitung Seite 77

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 88
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 76

TROUBLESHOOTING (ELECTRICAL)

 Possible Problem Solution
Main A OPEN
Burnt 12 V cycling solenoid.
Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.
Wire connection broken. Replace broken wire.
Main A SHORTED
The 12-volt cycling solenoid is shorted
directly to ground.
Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.
Wire connection is shorted directly to the
ground.
Correct connection.
Main B OPEN
Burnt 12 V cycling solenoid.
Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.
Wire connection broken. Replace broken wire.
Main B SHORTED
The 12-volt cycling solenoid is shorted
directly to ground.
Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.
Wire connection is shorted directly to the
ground.
Correct connection.
Swing OPEN
Burnt 12 V cycling solenoid.
Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.
Wire connection broken. Replace broken wire.
Swing SHORTED
The 12-volt cycling solenoid is shorted
directly to ground.
Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.
Wire connection is shorted directly to the
ground.
Correct connection.
Throttle solenoid open
Burnt 12 V cycling solenoid.
Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.
Wire connection broken. Replace broken wire.
Throttle solenoid shorted
The 12-volt cycling solenoid is shorted
directly to ground.
Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.
Wire connection is shorted directly to the
ground.
Correct connection.
Fuel solenoid open
Burnt 12 V cycling solenoid.
Measure solenoid coil resistance. It should read 6
ohms. Replace burnt solenoid.
Wire connection broken. Replace broken wire.
Fuel solenoid shorted
The 12-volt cycling solenoid is shorted
directly to ground.
Measure solenoid coil resistance. It should read 6
ohms. Replace shorted solenoid.
Wire connection is shorted directly to the
ground.
Correct connection.
Seitenansicht 76