The definitions below describe the controls and functions
of the Engine/Generator Control Panel (Figure 5).
1. Gauge Unit Assembly This assembly houses the
various engine monitoring gauges. These gauges
indicate: oil pressure, water temperature, charging
voltmeter, fuel and engine speed RPM (tachometer).
A. Oil Pressure Gauge — During normal operation
this gauge be should read approximately 50 psi.
(345 kPa). When starting the generator the oil
pressure may read a little higher, but after the
engine warms up the oil pressure should return
to the correct pressure range.
B.  — During normal
operation this gauge be should read approximately
180°F (82°C).
C. Charging Voltmeter Gauge — During normal
operation this gauge indicate minimum 14 VDC
D. Fuel Gauge — Indicates amount of diesel fuel
available.
E. — Indicates engine speed in RPM’s
for 60 Hz operation. This meter should indicate
1800 RPM’s when the rated load is applied.
Figure 5. Engine/Generator Control Panel
Low Oil Pressre
High temp.
Over Crank
Over Speed
Engine Started
ECU
Intergrated Gauge Control
R
Low Oil Pressre
High temp.
Over Crank
Over Speed
Engine Started
ECU
Intergrated Gauge Control
R
2
3
4
5
6
9
7
8
10
11
12
15
14
13
F
F. 
 This LED will light
when the engine oil pressure drops to 14.2 psi
(98 kPa). This condition will cause the engine
to shut down.
 This LED will light
when the coolant temperature has reached
212°F (100°C). This condition will cause the
engine to shut down.
  This LED will light when
when the engine has attempted to start 3 times
and failed. The intervals between the 3 start
cycles is approximately 10 seconds.
  This LED will light when
when the engine is running at an unsafe speed.
This condition will cause the engine to shut
down.
 This LED will light when
when the engine has started and is operating
correctly.
2. When activated will turn on
control panel light.
3. — For operation at night, panel light
illuminates control panel for ease of reading meters
and gauges. Make sure panel light switch is in the OFF
position when light is not in use.