PAGE 26 —DA7000 SERIES A.C. GENERATORS— OPERATION AND PARTS MANUAL — REV. #4 (08/07/09)
DA7000 SERIES GENERATORS—SETUP
Fan Belt Tension
A slack fan belt may contribute to overheating, or to
insufficient charging of the battery. Inspect the fan belt for
damage and wear and adjust it in accordance with the Kubota
Engine Owner's Manual.
The fan belt tension is proper if the fan belt bends 10 to 15
mm (Figure 13) when depressed with the thumb as shown
below.
Figure 13. Fan Belt Tension
NEVER place hands near
the belts or fan while the
generator set is running.
CAUTION - ROTATING PARTS
Air Cleaner
Inspect the air cleaner element for dirt amd excessive wear.
If the air cleaner is dirty or bady worn, replace immediately.
DO NOT run the engine with a defective air cleaner, severe
engine damage could occur.
For additional information regarding the air cleaner, reference
the maintenance section of this manual.
Figure 14. Battery Connections
ALWAYS
disconnect the negative terminal FIRST and
reconnect negative terminal LAST.
Battery
This unit is of negative ground DO NOT connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid level are not
properly maintained. Add only distilled water when
replenishment is necessary.
DO NOT over fill. Check to see whether the battery cables
are loose. Poor contact may result in poor starting or
malfunctions.
Always
keep the terminals firmly tightened.
Coating the terminals with an approved battery terminal
treatment compound. Replace battery with only
recommended type battery.
The battery is sufficiently charged if the specific gravity of
the battery fluid is 1.28 (at 68° F). If the specific gravity
should fall to 1.245 or lower, it indicates that the battery is
dead and needs to be recharged or replaced.
Before charging the battery with an external electric source,
be sure to disconnect the battery cables.
Battery Cable Installation
ALWAYS be sure the battery cables (Figure 14) are properly
connected to the battery terminals as shown below. The Red
Cable is connected to the positive terminal of the battery,
and the Black Cable is connected to the negative terminal
of the battery.
CAUTION - BATTERY SERVICING SAFETY
Inadequate battery connections may cause poor starting
of the generator, and create other malfunctions.
CAUTION - BATTERY SERVICING SAFETY